ABT 4th and 5th DSM Amendment Concept
- ABT 4th DSM Amendment
- Frequency Band has been tightened to 50.05 to 49.85
- Deviation Price Vector linked to Daily Average Area Cleaning Price(ACP) in Day Ahead Market of Power Exchange.
- Cap Rate For all Generator.
- In the event of sustained deviation from SG in one direction (positive or negative) by any regional entity , such regional entity shall have to change sign of their deviation from schedule, at least once, after every 6 time blocks.
- Calculation 1% Deviation During Day.
- Pfactor Calculate by Equitation Given by DSM Regulations.
- Penalty count for sustain deviation.

- Summery of DSM 4th Amendment
- Over Injection
Frequency( f) <= 50.04 Hz : Rate of UI charge is Minimum of calculated value as per Area Clearing Price(P) or Cap limit (3.0304 rupees).
Frequency (f) >= 50.05 Hz : Penalty rate of Over injection is as per ACP(P) value.Over Injection
Frequency( f) <= 50.04 Hz : Rate of UI charge is Minimum of calculated value as per Area Clearing Price(P) or Cap limit (3.0304 rupees).
Frequency (f) >= 50.05 Hz : Penalty rate of Over injection is as per ACP(P) value.Over Injection
- Under Injection
- Frequency(f) < 49.85 Hz :Deviation Charge - Rs 3.0304 Additional deviation charge(ADC) – Rs 3.0304 Total penalty = Rs 6.0608
- Frequency between 49.85-50.04 Hz :Deviation charge is Minimum of calculated value as per Area Clearing Price(P) or Cap limit (3.0304 rupees) If UI exceeds 12% of SG , then total charges = DC +ADC
DC = Minimum of calculated value as per Area Clearing Price(P) or Cap limit (3.0304 rupees)
ADC for 12% to 15% of SG = 20% of Minimum of ACP(P) or Cap rate(3.0304)
ADC for 15% to 20% of SG = 40% of Minimum of ACP(P) or Cap rate(3.0304)
ADC for >20% of SG = 100% of Minimum of ACP(P) or Cap rate(3.0304)
3. Frequency(f) >= 50.05 Hz : No penalty for under injection.
Sign Change
For two sign change violation , charges = 2x20% of Day deviation charge
Similarly ,For fifth sign change violation , charges = 5x20% of Day deviation charge
- Summery of 5th DSM Amendment
- Direction change 6 block to 12 block for the period up to 31.03.2020.
- For Period from 01.04.2020 sustained deviation in one direction for 6 time blocks.After one year development.
- Frequency changes 50.05 to 50.10
Last modified: Thursday, 24 October 2019, 6:04 PM